Separate kernel and user switches into separate objects

This commit is contained in:
Brandon Heller
2010-01-02 10:58:28 -08:00
parent 16c57ddb33
commit 1bb4412ff3
4 changed files with 124 additions and 129 deletions
+2 -2
View File
@@ -11,7 +11,7 @@ from ripcord.topo import FatTreeTopo
from mininet.logging_mod import lg, set_loglevel, LEVELS
from mininet.net import Mininet, init
from mininet.node import Switch, Host, Controller, ControllerParams, NOX
from mininet.node import KernelSwitch, Host, Controller, ControllerParams, NOX
from mininet.topo import TreeTopo
# built in topologies, created only when run
@@ -24,7 +24,7 @@ TOPOS = {'minimal' : (lambda: TreeTopo(depth = 2, fanout = 2)),
'fattree6' : (lambda: FatTreeTopo(k = 6))}
SWITCH_DEF = 'kernel'
SWITCHES = {'kernel' : Switch}
SWITCHES = {'kernel' : KernelSwitch}
HOST_DEF = 'process'
HOSTS = {'process' : Host}
+10 -4
View File
@@ -377,14 +377,20 @@ class Mininet(object):
return ploss
def ping_all(self):
'''Ping between all hosts.'''
self.ping()
'''Ping between all hosts.
@return ploss packet loss percentage
'''
return self.ping()
def ping_pair(self):
'''Ping between first two hosts, useful for testing.'''
'''Ping between first two hosts, useful for testing.
@return ploss packet loss percentage
'''
hosts_sorted = sorted(self.topo.hosts())
hosts = [hosts_sorted[0], hosts_sorted[1]]
self.ping(hosts = hosts)
return self.ping(hosts = hosts)
@staticmethod
def _parseIperf(iperfOutput):
+104 -109
View File
@@ -211,6 +211,102 @@ class Host(Node):
pass
class Switch(Node):
'''A Switch is a Node that is running (or has execed)
an OpenFlow switch.'''
def sendCmd(self, cmd):
'''Send command to Node.
@param cmd string
'''
if not self.execed:
return Node.sendCmd(self, cmd)
else:
lg.error('*** Error: %s has execed and cannot accept commands' %
self.name)
def monitor(self):
'''Monitor node.'''
if not self.execed:
return Node.monitor(self)
else:
return True, ''
class UserSwitch(Switch):
def __init__(self, name):
'''Init.
@param name
'''
Node.__init__(self, name, inNamespace = True)
def start(self, controllers):
'''Start OpenFlow reference user datapath.
Log to /tmp/sN-{ofd,ofp}.log.
@param controllers dict of controller names to objects
'''
if 'c0' not in controller:
raise Exception('User datapath start() requires controller c0')
controller = controllers['c0']
ofdlog = '/tmp/' + self.name + '-ofd.log'
ofplog = '/tmp/' + self.name + '-ofp.log'
self.cmd('ifconfig lo up')
intfs = self.intfs[1:] # 0 is mgmt interface
self.cmdPrint('ofdatapath -i ' + ','.join(intfs) +
' ptcp: 1> ' + ofdlog + ' 2> ' + ofdlog + ' &')
self.cmdPrint('ofprotocol tcp:' + controller.IP() +
' tcp:localhost --fail=closed 1> ' + ofplog + ' 2>' +
ofplog + ' &')
def stop(self):
'''Stop OpenFlow reference user datapath.'''
self.cmd('kill %ofdatapath')
self.cmd('kill %ofprotocol')
class KernelSwitch(Switch):
def __init__(self, name, datapath = None):
'''Init.
@param name
@param datapath string, datapath name
'''
self.dp = datapath
Node.__init__(self, name, inNamespace = (datapath == None))
def start(self, ignore):
'''Start up reference kernel datapath.'''
ofplog = '/tmp/' + self.name + '-ofp.log'
quietRun('ifconfig lo up')
# Delete local datapath if it exists;
# then create a new one monitoring the given interfaces
quietRun('dpctl deldp ' + self.dp)
self.cmdPrint('dpctl adddp ' + self.dp)
self.cmdPrint('dpctl addif ' + self.dp + ' ' + ' '.join(self.intfs))
# Run protocol daemon
self.cmdPrint('ofprotocol' +
' ' + self.dp + ' tcp:127.0.0.1 ' +
' --fail=closed 1> ' + ofplog + ' 2>' + ofplog + ' &')
self.execed = False # XXX until I fix it
def stop(self):
'''Terminate reference kernel datapath.'''
quietRun('dpctl deldp ' + self.dp)
# In theory the interfaces should go away after we shut down.
# However, this takes time, so we're better off to remove them
# explicitly so that we won't get errors if we run before they
# have been removed by the kernel. Unfortunately this is very slow.
self.cmd('kill %ofprotocol')
for intf in self.intfs:
quietRun('ip link del ' + intf)
lg.info('.')
class Controller(Node):
'''A Controller is a Node that is running (or has execed) an
OpenFlow controller.'''
@@ -240,105 +336,16 @@ class Controller(Node):
self.terminate()
class Switch(Node):
'''A Switch is a Node that is running (or has execed)
an OpenFlow switch.'''
def __init__(self, name, datapath = None):
class ControllerParams(object):
'''Container for controller IP parameters.'''
def __init__(self, ip, subnet_size):
'''Init.
@param name
@param datapath string, datapath name
@param ip integer, controller IP
@param subnet_size integer, ex 8 for slash-8, covering 17M
'''
self.dp = datapath
Node.__init__(self, name, inNamespace = (datapath == None))
def _startUserDatapath(self, controllers):
'''Start OpenFlow reference user datapath.
Log to /tmp/sN-{ofd,ofp}.log.
@param controllers dict of controller names to objects
'''
if 'c0' not in controller:
raise Exception('User datapath start() requires controller c0')
controller = controllers['c0']
ofdlog = '/tmp/' + self.name + '-ofd.log'
ofplog = '/tmp/' + self.name + '-ofp.log'
self.cmd('ifconfig lo up')
intfs = self.intfs[1:] # 0 is mgmt interface
self.cmdPrint('ofdatapath -i ' + ','.join(intfs) +
' ptcp: 1> ' + ofdlog + ' 2> ' + ofdlog + ' &')
self.cmdPrint('ofprotocol tcp:' + controller.IP() +
' tcp:localhost --fail=closed 1> ' + ofplog + ' 2>' +
ofplog + ' &')
def _stopUserDatapath(self):
'''Stop OpenFlow reference user datapath.'''
self.cmd('kill %ofdatapath')
self.cmd('kill %ofprotocol')
def _startKernelDatapath(self):
'''Start up reference kernel datapath.'''
ofplog = '/tmp/' + self.name + '-ofp.log'
quietRun('ifconfig lo up')
# Delete local datapath if it exists;
# then create a new one monitoring the given interfaces
quietRun('dpctl deldp ' + self.dp)
self.cmdPrint('dpctl adddp ' + self.dp)
self.cmdPrint('dpctl addif ' + self.dp + ' ' + ' '.join(self.intfs))
# Run protocol daemon
self.cmdPrint('ofprotocol' +
' ' + self.dp + ' tcp:127.0.0.1 ' +
' --fail=closed 1> ' + ofplog + ' 2>' + ofplog + ' &')
self.execed = False # XXX until I fix it
def _stopKernelDatapath(self):
'''Terminate reference kernel datapath.'''
quietRun('dpctl deldp ' + self.dp)
# In theory the interfaces should go away after we shut down.
# However, this takes time, so we're better off to remove them
# explicitly so that we won't get errors if we run before they
# have been removed by the kernel. Unfortunately this is very slow.
self.cmd('kill %ofprotocol')
for intf in self.intfs:
quietRun('ip link del ' + intf)
lg.info('.')
def start(self, controllers):
'''Start datapath.
@param controllers dict of controller names to objects
'''
if self.dp is None:
self._startUserDatapath(controllers)
else:
self._startKernelDatapath()
def stop(self):
'''Stop datapath.'''
if self.dp is None:
self._stopUserDatapath()
else:
self._stopKernelDatapath()
def sendCmd(self, cmd):
'''Send command to Node.
@param cmd string
'''
if not self.execed:
return Node.sendCmd(self, cmd)
else:
lg.error('*** Error: %s has execed and cannot accept commands' %
self.name)
def monitor(self):
'''Monitor node.'''
if not self.execed:
return Node.monitor(self)
else:
return True, ''
self.ip = ip
self.subnet_size = subnet_size
class NOX(Controller):
@@ -360,16 +367,4 @@ class NOX(Controller):
controller = nox_core_dir + '/nox_core',
cargs = '--libdir=/usr/local/lib -v -i ptcp: ' + \
' '.join(nox_args),
cdir = nox_core_dir, **kwargs)
class ControllerParams(object):
'''Container for controller IP parameters.'''
def __init__(self, ip, subnet_size):
'''Init.
@param ip integer, controller IP
@param subnet_size integer, ex 8 for slash-8, covering 17M
'''
self.ip = ip
self.subnet_size = subnet_size
cdir = nox_core_dir, **kwargs)
+8 -14
View File
@@ -8,12 +8,12 @@ from time import sleep
import unittest
from mininet.net import init, Mininet #, DATAPATHS
from mininet.node import Switch, Host, NOXController, ControllerParams
from mininet.node import KernelSwitch, Host, ControllerParams
from mininet.node import Controller
from mininet.topo import TreeTopo
# temporary, until user-space side is tested
DATAPATHS = ['kernel']
SWITCHES = {'kernel' : KernelSwitch}
class testMinimal(unittest.TestCase):
'''For each datapath type, test ping with a minimal topology.
@@ -24,15 +24,12 @@ class testMinimal(unittest.TestCase):
def testMinimal(self):
'''Ping test with both datapaths on minimal topology'''
init()
for datapath in DATAPATHS:
k = datapath == 'kernel'
for switch in SWITCHES.values():
controller_params = ControllerParams(0x0a000000, 8) # 10.0.0.0/8
mn = Mininet(TreeTopo(), Switch, Host, Controller,
mn = Mininet(TreeTopo(), switch, Host, Controller,
controller_params)
mn.start()
dropped = mn.ping_test()
dropped = mn.run('ping')
self.assertEqual(dropped, 0)
mn.stop()
class testTree(unittest.TestCase):
@@ -41,16 +38,13 @@ class testTree(unittest.TestCase):
def testTree16(self):
'''Ping test with both datapaths on 16-host topology'''
init()
for datapath in DATAPATHS:
k = datapath == 'kernel'
for switch in SWITCHES.values():
controller_params = ControllerParams(0x0a000000, 8) # 10.0.0.0/8
tree_topo = TreeTopo(depth = 3, fanout = 4)
mn = Mininet(tree_topo, Switch, Host, Controller,
mn = Mininet(tree_topo, switch, Host, Controller,
controller_params)
mn.start()
dropped = mn.ping_test()
dropped = mn.run('ping')
self.assertEqual(dropped, 0)
mn.stop()
#class testLinear(unittest.TestCase):
# '''For each datapath type, test all-pairs ping with LinearNet.'''